02 / FIRMWARE, UPDATES & APPLICATION PLANNING
|
Firmware & Updates
NO DIGITAL FIRMWARE
The analog module uses hardware range configuration and calibration rather than downloadable firmware.
RANGE CONFIGURATION
Record jumper positions, zero and span settings and the ordered measuring range before removal.
CALIBRATION CONTROL
Verify output scaling against the receiving instrument after installation or service.
|
Application Scenarios
PROCESS SIGNALS
Isolate and convert standard DC measurement signals between field and control equipment.
HAZARDOUS INTERFACES
Use the documented intrinsically safe version where signals originate in hazardous areas.
CABINET RETROFIT
Replace a matched plug-in amplifier while preserving backplane and range configuration.
|
Technical data
|
DEVICE TYPE
Isolation amplifier
|
SIGNAL INPUTS
0/4-20mA; 0/2-10V
|
BIPOLAR RANGES
±20mA; ±10V
|
|
SIGNAL OUTPUTS
Current or voltage
|
RESPONSE TIME
Below 50ms
|
CONNECTOR
96-pin DIN 41612
|
|
POWER OPTIONS
24-60V or 85-230V AC/DC
|
MOUNTING
BP902 backplane
|
BASIC ACCURACY
Approx. ±0.2%
|
Technical values apply to the exact documented revision. Verify the installed board marking, firmware baseline and receiving system before commissioning.
03 / BRAND & APPLICATIONS
|
Brand characteristics
| Measurement focus |
Camille Bauer develops compact instrumentation for accurate process and energy measurements. |
| Signal flexibility |
Configurable current and voltage ranges reduce spare-part variation across installed loops. |
| Galvanic isolation |
Separated circuits help limit ground-loop errors and potential differences. |
| Manual calibration |
Accessible zero and span adjustment supports controlled field commissioning. |
| Compact integration |
Plug-in construction preserves cabinet space in established SIRAX systems. |
|
Application fields
| Process plants |
Isolation and scaling of transmitter signals in monitoring and control loops. |
| Energy systems |
Conditioning of analog signals used in electrical and auxiliary measurements. |
| Panel engineering |
Compact signal conversion in instrument and automation cabinets. |
| Hazardous areas |
Interface of documented intrinsically safe measurement circuits. |
| Maintenance |
Like-for-like replacement of configured SIRAX plug-in amplifiers. |
|
Product references
|
Siemens
| CPU315-2DP |
ET200M |
IM153-2 |
SM321 |
| SM322 |
SM331 |
SM332 |
CP343-1 |
| FM350-1 |
PS307 |
6ES7134 |
6ES7135 |
| 6ES7151 |
6ES7972 |
6GK7443 |
6AV2124 |
| 6SL3055 |
6SE7090 |
6FC5210 |
6FX2001 |
|
Camille Bauer
| TV808 |
TV809 |
TV815 |
TV819 |
| V604S |
V624 |
V608 |
V610 |
| V611 |
V604 |
Q531 |
M561 |
| M562 |
DME401 |
DME406 |
A210 |
| A220 |
A230 |
PQ3000 |
LINAX A325 |
|